PROCON-Connect 1.2.0

Features

  • 104984: PROCON-Connect can couple with the u-OS Datahub and exchange tags. Details under u-OS Datahub.

  • 111800: SQLite data loggers can now also be created in-memory in addition to a file-based database. Details under Choosing the right database type.

  • 111803: The deletion cycles for data loggers can now also be configured on a minute basis.

  • 112537: The size of an SQLite database is now displayed in the Datalogger overview.

  • 111819: Multiple SQLite databases can now be created. The file path to the database is now also configurable and can also be located on a USB device or an SD card. Details under SQLite file based.

  • 104424: When opening the UI in an unlicensed state, a notification is displayed that can be used to activate demo mode directly. Details under Licensing.

  • 110964: The OPC UA driver can now be configured for each connection whether tags in status uncertain should be treated as status good. This allows writing to tags in status uncertain.

  • 110463: The visibility of the buttons in the connector overview and data logger overview has been improved.

Fixes

  • 109047: Fixed an issue that caused the licensing of an InfluxDB link to only work after a restart.

  • 109052: Fixed an issue that caused not all configuration changes to be saved when customizing an InfluxDB link.

  • 106807: Fixed an issue that meant that it was no longer possible to switch projects via the project management UI.

  • 110986: Fixed an issue that caused the interpolation to be performed incorrectly for a request over several tags of a data logger.

  • 108806: Fixed an issue that caused the Codesys driver to ignore the static kill configuration.

  • 108539: Fixed an issue that caused the OPC UA driver to not read structures in an optimized way.

  • 108982: Fixed an issue that caused the OPC UA driver to import strings with the wrong length.

  • 111629: Fixed an issue that caused connected cloud connectors to no longer display their status in the connector overview.

  • 111200: Fixed an issue that caused license containers not to be created correctly.

  • 110334: Fixed an issue that prevented connectors from being connected or disconnected across all UI elements.

  • 110727: Fixed an issue that caused an error message to be displayed when connecting to an MQTT broker with an untrusted certificate.

  • 110624: Fixed an issue that caused the number of messages for connections to Azure IoT Hub to be displayed incorrectly in the connector overview.

  • 108263: Fixed an issue that caused the OPC UA driver to not correctly support multiple kill variables per connection.

  • 112501: Fixed an issue that caused the driver status to be displayed incorrectly after stopping a driver service.

  • 112503: Fixed an issue that caused the Allen-Bradley driver to not read all tags after a restart.

Known issues

  • If a tag for a driver is imported via the telemetry UI, it does not automatically appear in the tag list. The page must be refreshed, e.g. by pressing F5. Only occurs on u-OS, installations/deployments under Windows and Linux are not affected.